Grace fireproof thickness chart

WebWhere T = Thickness of coating in inches, W = Weight of steel column in pounds per linear foot, and D = Heated perimeter of steel column section in inches. The following table lists the thicknesses in metric units. Steel Size M/D 1 Hr Min Thickness, mm. 1-1/2 Hr Min Thickness, mm. 2 Hr Min Thickness, mm. 3 Hr Min Thickness, mm. W6x12 25.9 2.35 ... WebNA. Non-Load Restricted. Beam Only Design for Roof Assemblies. UL S750. PDF. NA. S750 Unres All. S750 Unres MK6GF. S750 Unres Z106HY.

Spray Applied Fireproofing — United Spray

Webmethod 102-120 pcf unit weight, 3000 psi compressive strength, vibrated, 4 to 7 percent air. Min thickness as measured to crests of steel floor and form units, 2-1/2 in. 3. Welded … Webt = the wall thickness of the tube (in.) The thickness of Spray-Applied Fire Resistive Materials for ratings of 3/4, 1, 1-1/2, 2, 3 and 4 h of a steel pipe or tube can be determined by the equation: h = R - 0.20 4.43 (A/P) Where: R = the hourly rating (hrs). h = the thickness of Spray-Applied Fire Resistive Materials, minimum 1/4 in., maximum 3 ... small foldaway treadmill https://raycutter.net

MONOKOTE SPRAY-APPLIED FIREPROOFING Product selection guide

Websample and verify the thickness and density of the fireproofing in accordance with the provisions of ASTM E605 (current edition), Standard Test ... Grace & Co.–Conn., 62 WhittemoreAvenue, Cambridge, MA02140. In Canada, Grace Canada, Inc., 294 Clements Road, West,Ajax, Ontario, Canada L1S 3C6. ... http://www.ritewaythermal.com/wp-content/uploads/2015/09/MK-288R-Prod_Select_Guide.pdf http://www.isolatek.com/storage/designs_thickness/2024_ul/Intumescent/Y615.pdf small fold down dining table

Standards in Fireproofing - AWCI

Category:THICKNESS DETERMINATION FOR SPRAY-APPLIED …

Tags:Grace fireproof thickness chart

Grace fireproof thickness chart

CEMENTITIOUS FIREPROOFING 07812 - Rite-Way Thermal

Webthickness used on the tested beam to determine the thickness required in the real structure. The purpose here is to clarify the correct application of the equation for … WebNov 20, 2024 · polyamide (e.g. Intergard 251) at a thickness not exceeding 75 microns (3 mils). Alternatively, a two coat primer system, such as epoxy zinc (e.g. Interzinc 52) and tie coat (e.g. Intergard 269) may be used, and should not exceed 110 microns (4.5 mils) combined dry film thickness. Specific primers have been tested

Grace fireproof thickness chart

Did you know?

WebNov 24, 2024 · Application of MONOKOTE® Fireproofing can be made in the following sequence: For thicknesses of approximately 1⁄2 in. (13 mm) or less, apply in one pass. For thicknesses of 5⁄8 in. (16 mm) or greater, apply subsequent … http://www.isolatek.com/storage/designs_thickness/2024_ul/Wet%20Mix/X790.pdf

WebIt is in the fireproofing contrac- Thickness Test: This test is performed by using a thickness gauge, as it appears in the drawing. This gauge is approved by ASTM E605, and is used by Under- writers Laboratories. It is light, durable, and … http://avi-sa.com/datasheets/Product%20Datasheet_Monokote%20Z-106.pdf

WebThe min thickness of Spray-Applied Fire Resistive Materials required for various fire resistance ratings of contour sprayed or boxed wide flange columns are shown in the table below: Column Size W/D Min Thkns In. 1 Hr 1-1/2 Hr 2 Hr 3 Hr 4 Hr W6x9 0.33 15/16 1-1/4 1-9/16 2-1/8 2-11/16 W6x12 0.43 13/16 1-1/8 1-7/16 2 2-9/16 WebW R GRACE & CO - CONN — Type Strux 90/40. 3. Steel Floor and Form Units* — Composite 1-1/2, 1-5/8, 2 or 3 in. deep galv units or 4-1/2 in. deep noncomposite galv units. Fluted units may be uncoated or phosphatized/painted. Min gauges are 22 MSG for fluted and 20/20 MSG for cellular units. The following combinations of units may be used:

WebGrace Fireproofing Products MONOKOTE® MK-6®, MK-6/HY® and MK-6s Product data and application instructions Product Description Monokote® MK-6®/HY® and MK-6s are …

Weba. Application of Type Z-106 fireproofing can be made in the following sequence: 1. For thickness of approximately 13mm (1/2 in.) or less, apply in one pass. 2. For thickness of 16mm (5/8 in.) or greater, apply subsequent passes after the first coat has set. b. Type Z-106 fireproofing material shall not be used if songs from the movie jerseyhttp://www.ritewaythermal.com/wp-content/uploads/2015/09/Monokote-MK-6HY-Spec-Data-579127.pdf songs from the movie hangoverWebFlow Charts UL Designs & Thicknesses for Isolatek’s passive fireproofing materials for the commercial and construction industry. For the most current UL designs, please visit the … songs from the movie goodfellashttp://www.archcoatings.com/product-pdfs/Grace%20products/Z106.pdf songs from the movie leap yearWebThe thickness of Spray-Applied Fire Resistive Materials shown in the table below are only applicable when the beams are supporting solid, normal weight, concrete slabs or floor assemblies containing only fluted floor or form units, topped with normal weight concrete. ... GRACE KOREA INC —Types MK-6/HY, MK-6/HY Extended Set, MK-10 HB, MK-10 ... songs from the movie meganWebSOUTHWEST TYPE 5GP A 15 lb./ft³ (240 kg/m³) SFRM intended for the fire protection of interior structural columns, beams, joists, decks, walls, roofs, girders, floors and pre-cast concrete units. It is tested and certified for fire resistance ratings up to 4 hours. Southwest Type 5GP is a trademark of the Southwest Fireproofing Products Company. small foldable workout benchWeb300 Series / ISOLATEK. ®. Type 300 Series &. CAFCO 400 / ISOLATEK Type 400 Series. Quick Resources. songs from the movie juice